Disassembly of the three core components of the LKD anti-blocking sulfide gun: Filter, Safety Valve, and High-Efficiency Nozzle - Comprehensive Analysis

Introduction

In the previous article, we discussed the on-site pain points of the sulfur acid sulfonation gun and the overall design concept of the LKD product. This article focuses on the product hardware and elaborates on the new features such as the precision filter for liquid sulfur import, the overpressure protection safety valve for insulated steam, the working principle and key parameters of the GH3 series high-efficiency nozzles, as well as the selection method, to facilitate quick matching of the device's operating conditions for everyone.

LKD Anti-Blockage Sulphur Gun

New Feature 1: Precise Filter for Liquid Sulfur Import

1. Function and Design Background

The liquid sulfur pipelines and storage tank area are made of carbon steel. Corrosion-generated iron sulfide will fall into the liquid sulfur and be transported along with the liquid sulfur to the sulfide gun, causing the sulfide gun to get clogged during operation, which may lead to the shutdown or reduction of production in the plant. The traditional solution is to install an external filter on the liquid sulfur pipeline before the sulfide gun. However, this solution has problems such as large space occupation, difficulties in insulation and heating, and inconvenience in cleaning. Moreover, due to poor insulation, the liquid sulfur may solidify in the filter, becoming a new blockage point.

The anti-blocking sulfide gun integrates a precise filter directly at the liquid sulfur inlet of the sulfide gun. Before the liquid sulfur enters the gun body, it passes through the filter. Particles larger than the filtration accuracy of iron sulfide and solid impurities are intercepted online, and the clean liquid sulfur enters the gun body to participate in the atomization combustion, cutting off the blocking path at the source. The filter is equipped with a steam insulation jacket, which works in coordination with the sulfide gun's insulation system to ensure that the liquid sulfur is always in a flowing temperature range of 135 to 155 degrees Celsius, and will not solidify in the filter.

2 Structure Composition

The precision filter is mainly composed of the filter cylinder (with a steam insulation jacket), wedge-shaped mesh filter element, quick-opening upper cover, discharge port, differential pressure interface, etc. The structure is shown in Figure 3-1. The filter element adopts a removable design. By opening the quick-opening upper cover, the entire filter element can be removed for cleaning or replacement without disassembling the pipeline. A discharge port is set at the bottom of the cylinder to discharge the intercepted impurities and empty the liquid sulfur. A differential pressure transmitter can be optionally equipped to achieve online blockage monitoring.

Figure 1 Schematic diagram of the liquid sulfur precision filter structure

3 Working Principle

The liquid sulfur enters the filter chamber from the outside through the inlet. Under the effect of pressure difference, it passes from the outside to the inside through the wedge-shaped mesh filter element. Sulfuric iron particles and solid impurities with a particle size greater than the filtration accuracy (≤2mm) are intercepted on the outer surface of the filter element and deposited at the bottom of the chamber. The clean liquid sulfur flows through the inner cavity of the filter element and exits through the outlet to the sulfide gun. The filtration accuracy of the filter element (≤2mm) is smaller than the minimum nozzle diameter (3mm), ensuring that the liquid sulfur passing through the filter will not clog any type of nozzle. The flow area of the filter element is not less than three times the cross-sectional area of the liquid sulfur pipe, with a small initial pressure difference and a large capacity for pollutant absorption, which can effectively extend the cleaning cycle.

The insulation jacket is supplied with 0.3 to 0.4 MPa saturated steam to maintain the temperature of the liquid sulfur in the filter at 135 to 155℃, preventing the liquid sulfur from solidifying. The condensate water from the jacket is discharged through the bottom drain valve. As impurities gradually accumulate, the pressure difference between the filter before and after increases. When the pressure difference reaches 0.15 MPa, the filter element should be cleaned in time.

Key technical parameters

Operating Red Line: The interior of the filter contains pressurized and high-temperature liquid sulfur. It is strictly prohibited to open the upper cover or remove the core under pressure; before maintenance, the valves must be isolated and the pressure must be released to drain the internal sulfur medium completely.

New Feature Two: Overpressure Protection Safety Valve for Insulation Steam

1 Function and Design Background

The insulation steam jacket of the sulfidation gun is inserted into the incinerator for sulfur combustion and is exposed to high temperatures for a long time. When the sulfur acid production unit is temporarily shut down, the temperature of the incinerator exceeds 300℃, or if the insulation steam inlet and outlet valves are simultaneously closed due to an error operation, the condensed water accumulated in the jacket will rapidly vaporize due to the high temperature inside the furnace, and the steam cannot be discharged in time. The pressure in the jacket will suddenly increase and, once it exceeds the bearing limit of the expansion joint (design pressure 1.6 MPa), the expansion joint will burst, causing steam leakage and even personal injury accidents. The expansion joint is a 316L corrugated pipe with a wall thickness of only 0.8 mm, which is the weakest part of the gun body.

To solve the problem of expansion joint damage caused by overpressure during the use of the sulfidation gun, an elastic safety valve is added to the insulation steam jacket of the anti-blocking sulfidation gun. During normal operation, the pressure in the jacket is 0.3 - 0.4 MPa, and the safety valve is in a sealed and closed state; when the pressure in the jacket abnormally increases to the set pressure of 0.8 MPa, the safety valve automatically jumps and discharges pressure, keeping the pressure in the jacket always below the design pressure of the expansion joint (1.6 MPa); when the pressure drops back to the seat pressure (not less than 90% of the set pressure), the valve disc re-closes and returns to the sealed state.

2 Working Principle

The safety valve is of a direct load spring-loaded full opening structure. The pressure in the jacket acts on the valve disc below, balancing with the spring preload force: when the pressure is below the set pressure, the spring force causes the valve disc to press against the valve seat and maintain a seal; when the pressure reaches the set pressure, the medium force overcomes the spring force, and the valve disc rapidly opens to the full stroke, and the steam in the jacket is discharged through the discharge pipe to a safe position; when the pressure drops to the seat pressure (not less than 90% of the set pressure), the valve disc re-closes. The set pressure of the safety valve has been tested and qualified before leaving the factory and is sealed; users are not allowed to adjust it themselves.

Table 1 Main Technical Parameters of the Safety Valve

Note: The safety valve is the last line of defense for overpressure protection and cannot replace proper operation. Under any circumstances, it is strictly prohibited to simultaneously close the inlet and outlet valves of the insulated steam.

GH3 Series High-Efficiency Nozzle

The high-efficiency nozzle is specially designed for the atomization combustion of liquid sulfur, featuring outstanding high-temperature resistance, corrosion resistance, and wear resistance. It adopts a streamlined structure and uses a precise integrated forming process, combined with high-strength alloy materials. The nozzle and nozzle seat adopt a hard-sealing method, effectively solving the sealing leakage problem caused by thermal contraction and expansion when the device is shut down, facilitating maintenance and disassembly. Under continuous operation conditions, the nozzle can withstand 1000 cold-hot alternating impacts and achieve 10 years of no leakage use. The inner wall of the flow channel is mirror-polished, which can effectively reduce the risk of sulfur liquid adhesion and sulfur accumulation, ensure long-term atomization stability, and reduce the generation of vortices and dead corners. This nozzle can maintain stable operation for 36 months under harsh conditions of the sulfur incineration furnace.

Working principle

The efficient nozzle employing a two-stage Raoult nozzle technology can significantly enhance the centrifugal force of liquid sulfur. The front end of the Raoult nozzle is designed to gradually contract to a narrow throat, and then gradually expand behind the throat. After passing through the first Raoult nozzle and being accelerated, the liquid sulfur enters the second nozzle and is further accelerated in the second nozzle. After passing through the second narrow throat, it is ejected from the nozzle. This structural design enables the liquid sulfur to effectively convert static pressure energy into kinetic pressure energy under the effect of the nozzle cross-sectional area change, thereby providing power for the high-speed spraying and atomization of the liquid sulfur. The liquid sulfur is accelerated through the nozzle flow path and enters the atomization zone. Under the action of shear force and pressure difference, it rapidly breaks into fine particles, forming a uniform cone-shaped jet of mist. During the atomization process, the fluid generates high-speed rotation through the precisely designed swirl chamber, enhancing the centrifugal atomization effect and further refining the atomized particles, increasing the surface area for the combustion reaction. Meanwhile, the geometric matching between the swirl chamber and the nozzle orifice has been optimized through multiphase flow simulation to ensure a concentrated and stable distribution of atomization particle sizes. In a high-temperature environment, the microstructure of the material remains dense and uniform, inhibiting the penetration of sulfur vapor and the expansion of thermal fatigue cracks.

Figure 2: Sectional view of the efficient nozzle

Figure 3: Photograph of the actual high-efficiency nozzle

Nozzle core performance

Flow regulation ratio: 1:2

Pressure regulation ratio: 1:3 (0.4 - 1.3 MPa)

Particle passage: 3×5mm

High-temperature stability: 1040℃

Mechanical properties: Tensile strength ≥ 795 MPa, elongation ≥ 50%

Corrosion resistance: Can resist sulfuric acid corrosion in liquid sulfur and can be used for a long time in high-temperature oxidative environment

Atomization particle size: 70% particles < 20 μm, no residue after burning liquid sulfur

Atomization angle: 60° - 110°, the nozzle angle can be adjusted according to the actual burner structure requirements

Product advantages

The nozzle internals are made of high-temperature alloy, which effectively resists the wear caused by liquid sulfur impurities and the corrosion of high-temperature dilute sulfuric acid, and can be used continuously at a temperature of 1100℃; the streamlined flow channel design reduces the retention area and avoids local overheating and coking.

The rotating multi-layer solid fog nozzle further optimizes the distribution of the combustion field, effectively controlling the intense combustion of liquid sulfur. Through the coordinated combustion of multiple layers of flow, low nitrogen combustion is achieved, significantly reducing the generation of NOx, and thereby reducing NOx emission pollutants.

The high negative pressure zone at the nozzle outlet has no liquid sulfur droplets falling, ensuring that the fuel is fully atomized and vaporized, avoiding the flushing of the furnace wall by unburned liquid droplets, preventing the accumulation of liquid sulfur in the furnace and non-steady-state combustion. The atomization and complete combustion process are highly coordinated, achieving near-zero residual sulfur in the sulfur incineration furnace.

The nozzle holes are concentric with the liquid sulfur pipe, which can ensure a symmetrical and stable flow field, avoiding uneven spraying and wear. The nozzle gun has a mirror-like inner wall and is combined with a precise streamline structure. After shutdown, there will be no liquid sulfur accumulation in the nozzle gun, which can effectively prevent blockage when restarting, and its performance is far superior to industry standards.

LKD Anti-blockage Sulfur Gun Quick Selection Explanation

Table 2 LKD Series Anti-block Sulfur Gun Selection Data Sheet

Selection Example: LKD-TFA-A8S-W-S1-1F —— Online cleaning anti-block sulfur gun, equipped with a precision filter and safety valve, with a flow rate of 5 to 10 t/h, nozzle diameter of 8 mm, 310S helix, Raoullet nozzle, 310S gun body, liquid sulfur connection DN50×25 PN16, installation flange DN100, double flange stainless steel hose.

Closing Preview

In the next post, we will focus on on-site practical operations: installation and commissioning, daily inspection and maintenance, rapid handling of common faults, safety precautions, key points for frontline operators and maintenance personnel to collect.